Skip to content

Our manuscript, "Interpretation of the Outputs of Deep Learning Model Trained with Skin Cancer Dataset" was published as a letter article in the Journal of Investigative Dermatology today (https://www.jidonline.org/article/S0022-202X(18)31992-4/fulltext).

When we train a CNN model, we somtimes get a disappointing Top-1 accuracy. I also suffered this problem and I did not understand exactly what was wrong at that time. When my early version of the 12DX paper was reviewed in JAMA dermatology 2 years ago, the biggest reason for rejection was the low Top-1 accuracy.


However, unlike general object recognition studies, it is very difficult to determine medical research results with Top-1 accuracy, and it is important that the AUC can be high even with a low Top-1 accuracy. If you look carefully, most of medical AI researches have used AUC rather than Top-(n) accuracy.

Because of small and imbalanced training data in medical researches, the analysis of each class as Top-(n) accuracy is inadequate (but the mean Top-(n) of all classes is meaningful). Top-(n) accuracy of each classes vary whenever we repeat the training of CNN with imbalanced dataset. Therefore, we should see the corrected value while using thresholds of each classes, that is ROC curve.

With the AUC results, we published "Classification of the Clinical Images for Benign and Malignant Cutaneous Tumors Using a Deep Learning Algorithm" (https://www.jidonline.org/article/S0022-202X(18)30111-8/fulltext)

There was a debate that my 12DX algorithm is not sensitive (low top-1 accuracy) with the ISIC dataset (Automated Dermatological Diagnosis: Hype or Reality?; https://www.jidonline.org/article/S0022-202X(18)31991-2/fulltext).

 

There was an additional problem as well as the Top accuracy problem.

When we analyze a clinical image, "the problem of judging whether it is melanoma or not" is easier than "the problem of matching the type of cancer".

Analyzing the output of the AI ​​(CNN) model is equivalent to "the problem of matching the type of cancer", and analyzing the ratio of output is proper if we want to analyze the problem of judging "whether cancer or not".

We interpreted the ratio of melanoma output and nevus output rather than using melanoma output alone.

RATIO (Melanoma Index) = melanoma output / (melanoma output + nevus output).

The clinical image of skin cancer consists of a nodular lesion and a background. If you want to concentrate on only the lesion, we need to analyze it with RATIO as above to get more accurate results.

In the attached photograph, (b) is "matching what cancer is" and (a) is judging "whether it is cancer or not".

We made web-DEMO (http://dx.medicalphoto.org), and we have made it possible to show what conclusions are coming up depending on the Top-5 output and how it is interpreted.

 



번호 제목 글쓴이 날짜 조회 수
1581 MS bot framework [3] WHRIA 2020.06.13 99
1580 file lock WHRIA 2020.09.22 99
1579 popup WHRIA 2020.12.31 99
1578 KMA 연수교육 주소 WHRIA 2016.10.05 100
1577 opencv rotate WHRIA 2019.03.09 106
1576 caffe WHRIA 2016.10.19 106
1575 indexeddb [2] WHRIA 2021.02.07 106
1574 fast rcnn WHRIA 2017.01.08 107
1573 high impact journals WHRIA 2019.04.07 112
1572 PHP7 으로 업그레이드 WHRIA 2016.05.05 116
1571 공유 메모리 예제 WHRIA 2016.09.09 121
1570 벤츠 E300 2010 년형 터치스크린 자가 수리 WHRIA 2015.12.25 122
1569 Visual Studio 필요없는 파일 삭제 for SVN file WHRIA 2016.09.04 125
1568 pytorch optimize WHRIA 2020.08.01 126
1567 은행은 믿을 곳이 못 되는군... WHRIA 2019.07.12 127

Powered by Xpress Engine / Designed by Sketchbook

sketchbook5, 스케치북5

sketchbook5, 스케치북5

나눔글꼴 설치 안내


이 PC에는 나눔글꼴이 설치되어 있지 않습니다.

이 사이트를 나눔글꼴로 보기 위해서는
나눔글꼴을 설치해야 합니다.

설치 취소